| HP BladeSystem solutions start with a either a c7000 or c3000 Enclosure. For the c3000 Enclosure, it can be added with c3000 power supplies, Active Cool Fans, a c3000 DVD drive, and if needed, an optional local KVM module. Once the enclosure has been selected, the following components can be added | networking interconnect modules, HP ProLiant and Integrity Server Blades, and optional Insight Control Environment for BladeSystem management software. |
The HP BladeSystem c3000 enclosure has the flexibility to scale from a single enclosure holding up to 8 blades, to a rack containing 7 enclosures holding up to 56 blades, the c-Class infrastructure is designed to meet the needs of today”s businesses. The c3000 enclosure is designed for several markets
Remote sites or branch offices holding between 3 and 8 servers, and in deployment sites such as retail stores, branch offices, manufacturing sites, and wiring closets. This enclosure is also designed for harsh environments not found in modern datacenters (high ambient temperatures, dusty environments, and in ships, airplanes, platforms, and vehicles).
Small and medium businesses, who own between 3 and 100 servers. The enclosure is designed for use with management devices such as local KVM switches for local administration.
Datacenters with special power and cooling constraints, such as datacenters needing DC powered racks, and/or datacenters with low power & cooling capacities (under 3000 watts per rack).
HPC clusters with InfiniBand interconnection, where the applications need a 1 to 1 IB network subscription ratio between physical nodes in the compute cluster.
What”s New
Support for Redundant Onboard Administrator module for c3000 tower enclosure.
| Product FeaturesFeature | Description |
Models
| HP BladeSystem c3000 Single-Phase Enclosure | 437504-B21 |
| NOTE | Includes 2 Power Supplies, 4 Fans, a DVD drive, rail kit, and 8 Insight Control Environment Licenses |
| HP BladeSystem Single-Phase c3000 Enclosure | 437502-B21 |
| NOTE | Includes 2 Power Supplies, 4 Fans, a DVD drive, rail kit, and 8 Insight Control Environment 30 Day Trial Licenses. |
| HP c3000 Tower Onboard Administrator Module, FIO | 461514-B21 |
| NOTE | This module is required for 458034-B21 and AH351A. |
| HP c3000 Dual Onboard Administrator Module | 488100-B21 |
| NOTE | Second Onboard Administrator Module for the DDR2 OA module included in (P/N 508668-B21 and AH257B). |
Functions
| Each c3000 enclosure is built with the following functions | Up to 8 half-height and/or up to 4 full-height server blades and/or storage blades per enclosure. |
Up to 3 different interconnect fabrics (Ethernet, FC, IB, iSCSI, SAS, etc.) supported simultaneously within the enclosure.
A single-phase power subsystem - for flexibility in connecting to datacenter power, or to UPS”s or to low-line wall outlets.
PARSEC enclosure design - Parallel, redundant and scalable cooling and airflow design
Four (4) to Six (6) Active Cool fans
Fully redundant design - no single point of failure; redundant interconnections between servers and interconnect modules; a mid-plane with no active components; redundant cooling using Active Cool fans; all devices are hot-pluggable and customer replaceable.
Best performance per watt - lower wattage per server blade, in comparison to rack-mounted servers
Full AC redundancy - with no power zones.
Single or redundant Onboard Administrator management modules (optional active-standby design)
| Onboard Administrator management module is built in to the enclosure with the following functions | Robust, multiple enclosure setup and control |
Reports asset and inventory information for the devices in the enclosure
Reports thermal and power information, including real-time actual power usage per server and per enclosure
ront-mounted Insight Display for easy management at the deployment site
Integrated access to all server blade iLOs from a single cable
Provides integrated access to interconnect bay device management ports from the single Onboard Administrator cable
Single sign-on capability for all devices in the enclosure
Role-based security locally and/or with LDAP directory services
Provides a wizard-based initial setup process for easy configuration
An optional DVD drive for local software deployment, and HP SmartStart deployment
An optional local KVM interface for connection to KVM switches
Benefits
| A BladeSystem c3000 enclosure provides the following benefits | With local and remote hardware management integrated across the solution, one full enclosure can be managed as easily as one server. |
| Scalable | Management and network interconnects extend scalability beyond a single enclosure, allowing resources to be pooled and shared across multiple enclosures. |
| Investment protection | Accommodates multiple server and network designs in one enclosure. |
Lower costs per server, in comparison to rack-mounted servers
Lower power consumption, in comparison to rack-mounted servers
| Service and management | Allows multiple administrators to remotely access and maintain multiple servers & interconnect devices simultaneously. |
Technical Specifications
| Zones or Quadrants | The c3000 enclosure is divided into 2 zones or quadrants by the horizontal support metalwork. Within each zone a removable divider is used to support half height devices. To install a full-height blade in any zone this divider must be removed. An optional mini-divider support bracket is included with every c3000 enclosure. As a consequence of using the mini-divider in the top, zone, this zone can only contain one full height blade and 2 half-height blades. The bottom zone can contain either 4 half-height blades, or by removing the divider, it can contain 2 full-height blades. |
NOTE
| Storage or tape blades can be installed in the same zone as both full-height and half-height blades, a bracket ships with each SB40c that allows a half-height blade to be mounted to the left side of a storage or tape blade.. Note | In this case, the SB40c or tape blade cannot be removed without first removing the half height blade and mounting bracket. |
| NOTE | For Mixed configurations of full height and half height population rules; please see the c3000 Enclosure installation and users guide at |
| http | //h71028.www7.hp.com/enterprise/cache/316682-0-0-0-121.html |
HP BladeSystem c3000 Server Blade Enclosure
Dimensions
| Height | 265 mm (10.4 in) |
| Width | 485 mm (19.1 in) |
| Depth | 835 mm (32.877 in) |
Shipping Dimensions
| Height | 584 mm (23.0 in) |
| Width | 607 mm (23.88 in) |
| Depth | 1013 mm (39.88 in) |
C3000 Enclosure Weight
| Unboxed | 65.8 kg (145 lb) approximately |
| Shipping | 88.5 kg (195 lb) approximately |
Max Enclosure Weight (approximated for fully loaded enclosure)
| Unboxed | 136 kg (300 lb) approximately |
| Shipping | 158.8 kg (350 lb ) approximately |
Temperature Range
| Operating | 10 to 35C (50 to 95F) |
| Non-Operating | -30 to 60C (-22 to 140F) |
Relative Humidity
(non-condensing)
| Operating | 20% to 80% |
| Non-Operating | 5% to 95% |
Wet Bulb Temperature
| Operating | 28C (82.4F) |
| Non-Operating | 38.7C (101.7F ) |
| NOTE | Operating temperature has an altitude derating of 1C (1.8F) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 45C (113F). Altitude maximum for storage is 70 KPa. |
Power
Input Requirements for c3000 Power Supplies
| Rated input voltage | 100 VAC to 240 VAC |
| Rated input frequency | 50 to 60 Hz |
Rated input current
per power supply
| 100VAC | 9.3Arms |
| 120VAC | 9.7Arms |
| 200VAC | 7.8Arms |
Power Cords
| Power supply to PDU/UPS | From power supply (c-13) to PDU/UPS (c-14) |
Output
Specifications
| Per AC Power Supply | 1200W @ 200VAC to 240VAC input |
900-W @ 120VAC input
800-W @ 100VAC input
Option Kits
Power Supply Dimensions
Size
| Height | 38.48 mm (1.515 in) |
| Width | 86.36 mm (3.4 in) |
| Depth | 190.5 mm (7.5 in) |
| Weight | 1.13 kg (2.5 lbs) |
Fan Option Shipping Dimensions
Size
| Height | 223 mm (8.75 in) |
| Width | 248 mm (9.75 in) |
| Depth | 403 mm (15.88 in) |
| Weight | 1.8 Kg (4.0 lbs) |
Power Specifications
NOTE
To review maximum system power ratings for facilities planning purposes use the Active Answers Power Calculator which is available via the online tool located at URL
| http | //www.hp.com/go/bladesystem/powercalculator |
Environment-friendly Products and Approach
End-of-life Management and Recycling
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to http
//www.hp.com/go/green . To recycle your product, please go to
| http | //www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. |
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at
| http | //www.hp.com/go/green . These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
Последнее изменение описания было произведено 03 Январь 2011 г.